Vol. 6 No. 4 (2026): November 2026
Open Access
Peer Reviewed

Development of Bolus Made from Silicone Rubber, Glycerol-Gelatin, and Aloe Vera-Gelatin Gel in Post-Mastectomy Breast Cancer Radiotherapy

Authors

Syarifah Annisatun Jariah , Lina Choridah , Dwi Rochmayanti , Suwardi

Downloads

Received: 2026-10-20
Accepted: 2026-11-09
Published: 2026-11-09

Abstract

This study aims to develop and compare the physical, dosimetric, and applicative characteristics of boluses made from silicone rubber, glycerol-gelatin, and aloe vera-gelatin gel for post-mastectomy breast cancer radiotherapy. The study used an experimental method with variations in material composition and thickness. The samples were boluses of the three materials, while the testing instruments and procedures included measuring relative electron density (RED), surface dose, homogeneity, and evaluating applicative characteristics. Data were analyzed descriptively by comparing the measurement results of each material with a comparison bolus and considering aspects of cost, setting time, form durability, and hygiene. The results showed that silicone rubber was superior in form durability and stability, but had the highest estimated manufacturing cost. Glycerol-gelatin showed advantages in terms of cost and increased surface dose, especially at a ratio of 2:3 with a thickness of 1.5 cm. Aloe vera-gelatin gel also has the potential to be an alternative material by considering the balance of physical and dosimetric characteristics. In conclusion, the three materials have different advantages and limitations, so their selection needs to be adjusted to dosimetric needs, applicative aspects, and costs. Further validation under conditions closer to clinical practice is necessary before routine implementation.

Keywords:

Aloe Vera Gel, Breast Cancer, Glycerol Gelatin, Radiotherapy and Silicone Rubber.

References

[1] M. Arnold et al., “Current and future burden of breast cancer: Global statistics for 2020 and 2040,” The Breast, vol. 66, pp. 15–23, 2022, doi: 10.1016/j.breast.2022.08.010.

[2] R. M. Branch, Instructional Design: The ADDIE Approach. New York, NY, USA: Springer, 2009, doi: 10.1007/978-0-387-09506-6.

[3] Centers for Disease Control and Prevention, “Recommendations for disinfection and sterilization in healthcare facilities,” 2023. [Online]. Available: https://www.cdc.gov/infection-control/hcp/disinfection-sterilization/summary-recommendations.html

[4] H. M. Dahn et al., “The use of bolus in postmastectomy radiation therapy for breast cancer: A systematic review,” Critical Reviews in Oncology/Hematology, vol. 163, Art. no. 103391, 2021, doi: 10.1016/j.critrevonc.2021.103391.

[5] D. Fajriani, A. Muttaqin, and M. Ilyas, “Pembuatan dan karakterisasi bolus berbahan silicone rubber RTV 00A,” Jurnal Fisika Unand, vol. 13, no. 5, pp. 704–710, 2024, doi: 10.25077/jfu.13.5.704-710.2024.

[6] Global Cancer Observatory, “Cancer fact sheet,” 2020. [Online]. Available: https://gco.iarc.fr/today/fact-sheets-cancers

[7] A. P. Hariyanto, F. U. Mariyam, L. Almira, Endarko, and B. H. Suhartono, “Fabrication and characterization of bolus material using propylene glycol for radiation therapy,” Iranian Journal of Medical Physics, vol. 17, no. 3, pp. 161–169, 2020, doi: 10.22038/ijmp.2019.39798.1537.

[8] International Atomic Energy Agency, Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, Technical Reports Series No. 398. Vienna, Austria: IAEA, 2000. [Online]. Available: https://www-pub.iaea.org/mtcd/publications/pdf/trs398_scr.pdf

[9] International Atomic Energy Agency, “Quality management system: Radiotherapy.” [Online]. Available: https://www.iaea.org/resources/hhc/medical-physics/radiotherapy/quality-management-system

[10] R. B. Jimenez et al., “Postmastectomy radiation therapy: An ASTRO-ASCO-SSO clinical practice guideline,” Journal of Clinical Oncology, vol. 43, no. 30, pp. 3292–3311, 2025, doi: 10.1200/JCO-25-01747.

[11] Y. Kong et al., “A dosimetric study on the use of 3D-printed customized boluses in photon therapy: A hydrogel and silica gel study,” Journal of Applied Clinical Medical Physics, vol. 20, no. 1, pp. 348–355, 2019, doi: 10.1002/acm2.12489.

[12] L. C. Leony, V. F. Hanif, E. Defira, S. Oktamuliani, A. Muttaqin, and M. Ilyas, “Comparison of absorbed dose in plasticine bolus and silicone rubber bolus,” Journal of Physics: Theories and Applications, vol. 6, no. 1, pp. 25–33, 2022, doi: 10.20961/jphystheor-appl.v6i1.59117.

[13] F. Li, W. Hu, H. Li, B. Li, and Y. Wang, “Bolus use in postmastectomy radiation therapy for breast cancer: A systematic literature review,” Technology in Cancer Research & Treatment, vol. 24, 2025, doi: 10.1177/15330338251344521.

[14] E. Liang et al., “3D printing technology based on versatile gelatin-carrageenan gel system for drug formulations,” Pharmaceutics, vol. 15, 2023.

[15] D. Lobo et al., “Surface dose measurements in chest wall postmastectomy radiotherapy to achieve optimal dose delivery with 6 MV photon beam,” 2021.

[16] F. A. Miéville, N. Pitteloud, V. Achard, G. Lamanna, O. Pisaturo, P.-A. Tercier, and A. S. Allal, “Post-mastectomy radiotherapy: Impact of bolus thickness and irradiation technique on skin dose,” Zeitschrift für Medizinische Physik, vol. 34, no. 4, pp. 542–554, 2024, doi: 10.1016/j.zemedi.2023.03.004.

[17] C. da M. Oliveira, F. F. Brüning, J. G. P. Lyra, S. Y. Zanetti, M. Funchal, and T. C. de O. Fernandes, “Manufacture and characterization of a bolus composed of water, bi-distilled glycerin, gelatin and formaldehyde,” Brazilian Journal of Radiation Sciences, vol. 8, no. 3, 2020, doi: 10.15392/bjrs.v8i3.1206.

[18] S. J. Thomas, “Relative electron density calibration of CT scanners for radiotherapy treatment planning,” The British Journal of Radiology, vol. 72, no. 860, pp. 781–786, 1999, doi: 10.1259/bjr.72.860.10624344.

[19] UC Agriculture and Natural Resources, “Water activity and its role in food preservation,” Mar. 2025. [Online]. Available: https://ucanr.edu/program/uc-master-food-preserver/article/water-activity-and-its-role-food-preservation-march-2025.

Author Biographies

Syarifah Annisatun Jariah, Imaging Diagnostic Study Program, Applied Master’s Program, Graduate School, Semarang Ministry of Health Polytechnic, Indonesia

Author Origin : Indonesia

Lina Choridah, Department of Radiology, faculty of Medicine, Public Health, and Nursing, Universitas Gadjah Mada – dr.sardjito Hospital, Yogyakarta, Indonesia

Author Origin : Indonesia

Dwi Rochmayanti, Imaging Diagnostic Study Program, Applied Master’s Program, Graduate School, Semarang Ministry of Health Polytechnic, Indonesia

Author Origin : Indonesia

Suwardi, dr. Kariadi Hospital, Semarang, Indonesia

Author Origin : Indonesia

Downloads

Download data is not yet available.

How to Cite

Syarifah Annisatun Jariah, Lina Choridah, Dwi Rochmayanti, & Suwardi. (2026). Development of Bolus Made from Silicone Rubber, Glycerol-Gelatin, and Aloe Vera-Gelatin Gel in Post-Mastectomy Breast Cancer Radiotherapy. International Journal of Science and Environment (IJSE), 6(4), 537–555. https://doi.org/10.51601/ijse.v6i4.828

Similar Articles