Experimental Analysis of Major and Minor Flow Losses in Centrifugal Pump Piping Systems

Authors

  • Syakri Syakri Program Studi Sarjana Terapan Teknik Mesin Produksi dan Perawatan, Politeknik Negeri Bengkalis, Indonesia
  • Burhan Hafid Program Studi Sarjana Terapan Teknik Mesin Produksi dan Perawatan, Politeknik Negeri Bengkalis, Indonesia
  • Abdul Gafur Program Studi Sarjana Terapan Teknik Mesin Produksi dan Perawatan, Politeknik Negeri Bengkalis, Indonesia

DOI:

https://doi.org/10.51601/ijse.v6i2.753

Abstract

 Pumping and piping systems play a crucial role in transporting fluids in industrial and laboratory applications. However, energy losses occurring within the piping network can significantly reduce hydraulic performance and overall system efficiency. This study aims to experimentally analyze major and minor head losses in a centrifugal pump piping system under controlled laboratory conditions. The experimental setup employed a ½-inch PVC pipe with three piping configurations, namely a straight pipe, a 45° elbow, and a 90° elbow. Flow conditions were varied by adjusting the valve opening to produce different discharge rates. The measured parameters included flow rate and pressure difference, while flow velocity, Reynolds number, major head loss, and minor head loss were determined through standard fluid mechanics calculations. The experimental results indicate that increasing the flow rate leads to a significant increase in total head loss due to higher flow velocity and greater friction along the pipe wall. Furthermore, the 90° elbow generated higher minor head loss than the 45° elbow because the sharper change in flow direction produced stronger turbulence. These findings are consistent with fluid flow theory and demonstrate that both flow rate and fitting geometry have a substantial influence on energy losses. The results can serve as a useful reference for designing and operating more efficient centrifugal pump piping systems.

Downloads

Download data is not yet available.

References

[1]. N. Yusuf and Hariadi, “ISSN 2599-2081 EISSN 2599-2090 Faculty of Engineering UMSB EISSN 2599-2090 Faculty of Engineering UMSB,” Rang Teknik Journal, vol. 4, no. 1, pp. 1–8, 2021.

[2]. J. Vocational Engineering, T. Mechanical, and R. Alfridzi, "Attribution-ShareAlike 4.0 International Some rights reserved," Aug. 2025, doi: 10.12345/xxxxx.

[3]. Amrullah, Akbar Naro Parawangsa, and La Ode Ahmad Barata, “Experimental Test of Flow in Pipes with Variations of Centrifugal Pump Circuits,” Piston: Jurnal Teknologi, vol. 9, no. 1, pp. 1–6, 2024, doi: 10.55679/pistonjt.v9i1.57.

[4]. H. Poernomo et al., “Reinstallation of Centrifugal Pump Series Pipes in the PPNS Fluid Laboratory in Order to Improve Its Performance,” no. 1, 2025.

[5]. J. Vokasi Teknik, T. Mesin, and R. Alfridzi, “Attribution-ShareAlike 4.0 International Some rights reserved,” 2025, doi: 10.12345/xxxxx.

[6]. E. Julianto and E. Sarwono, “Minor Losses Analysis of Laboratory-Scale Fluid Flow Test Equipment,” December, vol. 10, no. 2, pp. 7–19, 2022, [Online]. Available: https://talenta.usu.ac.id/jd

[7]. M. Dahlan et al., “Comparative Analysis of Flow Losses in PVC and Galvanized Pipes Using 90 Degree Elbows,” 2024.

[8]. Sularso and Haruo Tahara, “(Book title: Pumps and Compressors),” 1983.

[9]. Analysis of Two-Phase Flow Characteristics (Liquid-Gas) at 90° Pipe Bends, ” 2024.

[10]. Çengel, Y.A., & Cimbala, J.M. (2020). Fluid Mechanics: Fundamentals and Applications (4th ed.). New York: McGraw-Hill Education.

[11]. White, F. M. (2021). Fluid Mechanics (9th ed.). New York: McGraw-Hill Education.

[12]. Munson, B.R., Young, D.F., Okiishi, T.H., & Huebsch, W.W. (2020). Fundamentals of Fluid Mechanics (9th ed.). Hoboken, NJ: John Wiley & Sons.

[13]. Fox, R.W., McDonald, A.T., Pritchard, P.J., & Leylegian, J.C. (2020). Fox and McDonald's Introduction to Fluid Mechanics (10th ed.). Hoboken, NJ: John Wiley & Sons.

[14]. Karassik, I. J., Messina, J. P., Cooper, P., & Heald, C. C. (2021). Pump Handbook (5th ed.). New York: McGraw-Hill Education.

[15]. Saputra, A., & Hidayat, R. (2023). Analysis of pressure loss (head loss) in piping systems using variations in PVC pipe diameters. Indonesian Journal of Mechanical Engineering, 18(2), 85–93.

[16]. Pratama, R., Nugroho, S., & Wibowo, A. (2022). The effect of discharge variations on flow losses in centrifugal pump piping systems. Jurnal Rekayasa Mesin, 13(3), 145–153. Kurniawan, D., & Setiawan, H. (2024). Experimental investigation of major and minor head losses in PVC piping systems with elbow fittings. AIP Conference Proceedings, 3157, 020012. https://doi.org/10.1063/5.0245678

[17]. Rahman, M., Hasan, M., & Islam, M. (2023). Experimental analysis of pressure drop and friction losses in PVC pipe flow. IOP Conference Series: Materials Science and Engineering, 1285, 012034. https://doi.org/10.1088/1757-899X/1285/1/012034

[18]. Putra, F., Syafri, M., & Nugraha, A. (2024). Experimental study on head loss characteristics in centrifugal pump piping systems. Journal of Physics: Conference Series, 2765, 012021. https://doi.org/10.1088/1742-6596/2765/1/012021

[19]. Siregar, R., & Nugroho, E. (2025). Analysis of the influence of fitting variations on flow energy losses in piping installations. Journal of Mechanical and Industrial Engineering, 9(1), 25-33.

Downloads

Published

2026-07-27

How to Cite

Syakri, S., Burhan Hafid, & Abdul Gafur. (2026). Experimental Analysis of Major and Minor Flow Losses in Centrifugal Pump Piping Systems. International Journal of Science and Environment (IJSE), 6(2), 2290–2298. https://doi.org/10.51601/ijse.v6i2.753

Issue

Section

Articles