Thermal comfort is essential for the human body to function effectively (at home, school, or in the workplace). A building's thermal performance is one of the primary factors determining the occupant's thermal comfort level. OTTV is an indicator of the building envelope's thermal performance. OTTV (Overall Thermal Transfer Value) is a measure of how much heat from outside the building enters the room through the building envelope (walls, glass, windows, and roof). This value is used to assess the building's thermal performance and energy efficiency. In Indonesia, Malaysia, and Singapore, OTTV performance is measured using formulas established by each country. This study aims to compare three methods for assessing heat transfer through the building envelope in the case of the same office building facade: Singapore's Envelope Thermal Transfer Value (ETTV), Malaysia's Overall Thermal Transfer Value (OTTV), and Indonesia's Overall Thermal Transfer Value (OTTV). These three methods historically originate from the same building regulatory framework, namely ASHRAE Standard 90A-1980 and the ASEAN-USAID/Lawrence Berkeley Laboratory energy conservation program, which were then adapted nationally by each country. A quantitative descriptive method with a comparative approach is applied to measure the Overall Thermal Transfer Value (OTTV) Performance, so that the measurements can be converted to applicable regulations. This case study clearly shows that with the same facade geometry and forming materials, different OTTV/ETTV index values are produced in the three countries with the same compliance result of Not Met. However, these results cannot be compared directly. The dominant heat gain component is solar radiation through fenestration. The implication is that practical design optimization needs to prioritize WWR control, glass thermal performance, and external shading design. Improvements in the U-value of the solid wall and the absorptivity of the solid wall are still beneficial, but in this case it is still less of a priority than solar heat control through fenestration.
Downloads
References
[1]. Basaria Talarosha (2005). Creating Thermal Comfort in Buildings. Journal of Industrial Engineering Systems Volume 6, No. 3 July 2005
[2]. Eddy Imam Santoso (2012). Indoor Thermal Comfort in Buildings in Humid Tropical Climate Areas. Postgraduate Program Journal, Brawijaya University
[3]. Lili Kusumawati M (2018). Thermal Energy Conservation in Humid Tropical Climate Areas. Case Study: Building C Campus A, Trisakti University. Trisakti University
[4]. Lili Kusumawati, Khotijah Lahji (2015). The Effect Of Fasade Design On Energy Efficiency, Trisakti University.
[5]. Lili Kusumawati, Riswandi Rohman (2025). Optimization Of Hotel Room Building Envelope In Malang For Energy Efficiency Using Ottv (Overall Thermal Transfer Value), Trisakti University.
[6]. Anak Agung Ngurah Aritama (2023). Factors Influencing the Thermal Comfort of Traditional Houses in Tenganan Pegringsingan Village. Patra Journal | ISSN 2684-947X |E-SSN 2684-9461, Udayana University.
[7]. George, L. (1980). Tropical Buildings (2nd edition). Jakarta: Erlangga Publisher.
[8]. Ardiyanto, A. (2015). Architectural Strategy in Determining the Thermal Performance of Paoa Colonial Office Buildings in Semarang. UGM.
[9]. Iyad Naufal Mas’um, Ria Rezky Amalia, Gusti Hardyanti Musda, Arinda Wahyuni (2024). Analysis of OTTV (Overall Thermal Transfer Value) as an Energy-Efficient Architectural Approach to the Building Envelope of the Makassar City Museum. Muslim University of Indonesia.
[10]. Director of Energy Conservation, Directorate General of New, Renewable Energy, and Energy Conservation, Ministry of Energy and Mineral Resources (2012). Energy Efficiency Guidebook for Building Design in Indonesia. Ministry of Energy and Mineral Resources.
[11]. Hermawan, Nasyiin Faqih, Annisa Nabila Arrizqi (2022). Thermal Comfort And Performance Of Vernacular Houses In Sayung Demak, Indonesia. Al-Qur’an Science University, Wonosobo, Islamic University Of Indonesia, Yogyakarta.
[12]. Fahdea Helfialna (2023). Analysis Of Thermal Comfort Level And User Satisfaction. Malikussaleh University, Lhokseumawe. Ribka Rehulina Ginting, Abdul Munir, Safwan (2020). Thermal Comfort Evaluation in the Bedroom of Ipau Female Dormitory in Banda Aceh. Syiah Kuala University
[13]. SNI 6389:2020 : Energy conservation of building envelope in building structures.
[14]. National Standardization Agency MS 1525:2014 : Energy efficiency and use of renewable energy for non-residential buildings - Code of practice (Second revision). Malaysian Standard.
[15]. Code On Envelope Thermal Performance for Buildings. Building and Construction Authority (BCA), Singapore.
[16]. Regulation of the Minister of Finance of the Republic of Indonesia No.: 249/PMK.02/2011. Performance Evaluation Measurement of the Implementation of Work Plans and Budgets of Ministries/Institutions.
[17]. Sheng, W., Zhang, L., & Ridley, I. (2020). The impact of minimum OTTV legislation on building energy consumption. Energy Policy, 136.
[18]. Chinmaya Biswal, Dhanujaya Naik Mude, Kummari Upender (2021). Concept Of Overall Thermal Transfer Value (Ottv) In Design Of Building Envelope To Achieve Energy Efficiency, Dept Of Mech, Sree Dattha Group of Institutions, Hyderabad, Telangana, India
[19]. Chou, S.K. & Lee, Y.K. (1988). A simplified overall thermal transfer value equation for building envelopes. Energy, 13(8), 657–670. doi:10.1016/0360-5442(88)90096-5
[20]. [20] Vijayalaxmi, J. (2010). Concept of Overall Thermal Transfer Value (OTTV) in Design of Building Envelope to Achieve Energy Efficiency. International Journal of Thermal & Environmental Engineering, 1(2), 75–80. doi:10.5383/ijtee.01.02.003
[21]. Chan, A.L.S. & Chow, T.T. (2013). Evaluation of Overall Thermal Transfer Value (OTTV) for commercial buildings constructed with green roofs. Applied Energy, 107, 10–24. doi:10.1016/j.apenergy.2013.02.010
[22]. Yumrutaş, R., Ünsal, M. & Kanoğlu, M. (2007). Estimation of total equivalent temperature difference values formultilayer walls and flat roofs by using periodic solution. Building and Environment, 42(5), 1878–1885. doi:10.1016/j.buildenv.2006.02.024
[23]. Zain-Ahmed, A., Sopian, K., Othman, M.Y.H., Sayigh, A.A.M. & Surendran, P.N. (2009). Overall Thermal Transfer Value of Residential Buildings in Malaysia. Journal of Applied Sciences, 9(11), 2130–2136. doi:10.3923/jas.2009.2130.2136
[24]. Zingre, K.T. et al. (2020). Thermal performance of double brick wall construction on the building envelope of high-rise hotel in Malaysia. Journal of Building Engineering, 29, 101163. doi:10.1016/j.jobe.2019.101163
[25]. Devgan, S., Kaur, J., Mathur, J. & Garg, V. (2010). Predetermined overall thermal transfer value coefficients for Composite, Hot-Dry and Warm-Humid climates. Energy and Buildings, 42(10), 1841–1851. doi:10.1016/j.enbuild.2010.05.019
[26]. Yik, F.W.H. & Wan, K.S.Y. (2005). An evaluation of the appropriateness of using overall thermal transfer value (OTTV) to regulate the envelope energy performance of air-conditioned buildings. Energy, 30(1), 41–71. doi:10.1016/j.energy.2004.03.001
[27]. Janda, K.B. & Busch, J.F. (1994). Worldwide status of energy standards for buildings. Energy, 19(1), 27–44. doi:10.1016/0360-5442(94)90106-6
[28]. Al-Qadhi, M.A. et al. (2025). Real-Time Monitoring and Development of a Localized OTTV Equation for Building Energy Performance. Civil Engineering Journal, 11(1). doi:10.28991/CEJ-2025-011-01-022
[29]. Natephra, W., Yabuki, N. & Fukuda, T. (2018). Optimizing the evaluation of building envelope design for thermal performance using a BIM-based overall thermal transfer value calculation. Building and Environment, 136, 128–145. doi:10.1016/j.buildenv.2018.03.032
[30]. Ramadhan, M.A. et al. (2025). Investigating Window Design Impact on OTTV Through BIM Modeling in Warm-Humid Indonesian Cities. Preprints. doi:10.21203/rs.3.rs-5316124/v1
[31]. Loekita, S. & Priatman, J. (2015). OTTV (SNI 03-6389-2011) and ETTV (BCA 2008) Calculation for Various Building's Shapes, Orientations, Envelope Building Materials: Comparison and Analysis. Civil Engineering Dimensions, 17(2), 108–116.
[32]. Wahyudi, M.B., Munir, S. & Afifuddin. (2023). The Effect of Shading Devices on OTTV Value of Office Buildings: Case Study of PT IKI Building. ASTONJADRO. doi:10.32832/astonjadro.v12i2.14255
[33]. Siu, C.Y. & Liao, Z. (2020). Is building energy simulation based on TMY representative? A comparative study on DOE reference buildings in Toronto. Energy and Buildings, 209, 109696. doi:10.1016/j.enbuild.2019.109696
[34]. Ballarini, I. et al. (2021). Detailed cross comparison of building energy simulation tools results using a reference office building as a case study. Energy and Buildings, 250, 111260. doi:10.1016/j.enbuild.2021.111260
[35]. Chou, S.K. & Chang, W.L. (1996). A generalized methodology for determining the total heat gain through building envelopes. International Journal of Energy Research, 20, 887–901.
[36]. Chou, S.K., Liew, H.T., Ko, J.R. & Goh, A. (2007). Envelope Thermal Transfer Value criterion for buildings in Singapore. Project report. Singapore: Building and Construction Authority.
[37]. ASEAN-USAID and Lawrence Berkeley Laboratory. (1992). Building Energy Conservation Project: Final Report.
[38]. Chow, W.K. & Chan, K.T. (1998). Comment on the Overall Thermal Transfer Value (OTTV) for Building Energy Control. Journal of Architectural Engineering ( ASCE), 4(4), 149. doi:10.1061/(ASCE)1076-0431(1998)4:4(149)
[39]. Priansyah, B.K. & Zulbahri. (2026). Evaluation of OTTV Values for Glass Facades in the Domestic Waiting Area at Sultan Hasanuddin Airport. Jurnal RISA (Riset Arsitektur), 10(1). doi:10.26593/risa.v10i1.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Rakhmat Setiadi, Inavonna

This work is licensed under a Creative Commons Attribution 4.0 International License.